Sale!

Sanwa DCL1200R clamp meter

Original price was: $2.00.Current price is: $1.00.

A True RMS AC clamp-meter with DMM capability is the Sanwa DCL1200R.

Category:

A True RMS AC clamp meter with DMM capability is the Sanwa DCL1200R.

The DCL1200R is an RMS value response type AC clamp meter/digital multimeter that is intended for measurements within the IEC61010-2-032 CAT.III 600V range. It is appropriate for measuring the current and voltage of low-voltage electrical equipment, circuitry, and power supply facilities.

With an accuracy of 1.7%, this clamp-meter can measure AC current up to 1200 Amperes.It has a backlit, 6000-count display. In addition to measuring AC/DC voltages, frequency up to 30 kHz, and capacitance, the tool is also a digital multimeter with an auto resistance feature that enables users to automatically measure resistances without having to adjust the range. The apparatus is also capable of

Diode and Continuity tests (with a buzzer). It can also wirelessly detect voltages of 15 V and above at 50/60 Hz.

The DCL1200R is compliant with the IEC61010-2-032, CAT.III 600V, IEC61010-031 safety standards, and IEC61326-1 EMC directives. It comes with TL-23a test leads, and a (C-DCL1000) carry case.

  • AC current measurable max. 1200A & DMM function
  • 6000 Count Display
  • True RMS
  • EF (Electric Field) sensing
  • Large LCD with Back light
  • Data hold
  • Range hold
  • Auto power save(3~) (non-cancelable)
  • Lightweight approx. 290g

Includes meter, test leads, carrying case and instructions.

 

Function Range Accuracy Resolution
ACA 400/1200A ±(1.7%+5) 0.1A
DCV 6/60/600V ±(0.7%+3) 0.001V
ACV 6/60/600V ±(1.7%+5) 0.001V
Auto resistance 6k/60k/600k/6MΩ ±(1.2%+4) 1 Ω
Resistance 600 Ω ±(2.2%+8) 0.1 Ω
Frequency 9.999/99.99/9.999k/30kHz ±(0.6%+4) 0.001Hz
Capacitance 100n/1000n/10 μ/100 μ2000 μF ±(3.7%+5) 0.1nF
Continuity Buzzer sounds at between 0 Ω and 155 Ω (±145 Ω)
Open voltage: approx. 0.4V
Diode test Open voltage: approx. 1.6V
Voltage detection Buzzer sounds and “-” is shown on LCD.
Input sensitivity: approx. 20V or over (50/60Hz)
Sampling rate 5 times/sec.
Bandwidth ACA 50/60Hz ACV 50-500Hz
Display 6000
Clamp diameter / Conductor size 42mm/20x54mm
Battery R03x2
Battery life Approx. 90 hrs. at DCV
(Alkaline battery / Backlight off)
Size/Mass H238xW95xD45mm / Approx. 290g